Car2012te series rectifier, Data sheet, Absolute maximum ratings – GE Industrial Solutions CAR2012TE series User Manual

Page 2: Electrical specifications

Advertising
background image

GE

Data Sheet

CAR2012TE series rectifier

Input: 85Vac to 264Vac; Output: 12 Vdc @ 2000W; 3.3Vdc or 5 Vdc @ 4A

February 9, 2014

©2013 General Electric Company. All rights reserved.

Page 2

Absolute Maximum Ratings

Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These are absolute stress ratings only, functional
operation of the device is not implied at these or any other conditions in excess of those given in the operations sections of the data sheet. Exposure

to absolute maximum ratings for extended periods can adversely affect the device reliability.

Parameter

Symbol

Min

Max

Unit

Input Voltage: Continuous

V

IN

0 264

V

AC

Operating Ambient Temperature

T

A

-10 70 °C

Storage Temperature

Tstg

-40

85

°C

I/O Isolation voltage to Frame (100% factory Hi-Pot tested)

2121

V

DC

Electrical Specifications

Unless otherwise indicated, specifications apply over all operating input voltage, load, and temperature conditions.

INPUT

Parameter

Symbol

Min

Typ

Max

Unit

Operational Range

V

IN

85 115/230 264

V

AC

Frequency Range (ETSI 300-132-1 recommendation)

F

IN

47 50/60 63

Hz

Main Output Turn OFF

V

IN

75 82

V

AC

Main Output Turn ON

80

88

Hysteresis between turn OFF and turn ON

3

5

Maximum Input Current (V

O

= V

O, set

, I

O

=I

O, max

) V

IN

= 100V

AC

I

IN

15.5
12.5

A

AC

V

IN

= 180V

AC

Cold Start Inrush Current (Excluding x-caps, 25C, <10ms,
per ETSI 300-132)

I

IN

40

A

PEAK

Efficiency (T

amb

=25C, V

O

= 12V) V

IN

100% load
50% load
20% load

10% load

115V / 230V

92 / 93.0
93 / 95.0
91 / 94.0

85 / 91.0

%

Power Factor (V

IN

=115/230V

AC

), I

O

= 50% I

O, max

I

O

= I

O, max

PF 0.98

0.99

Holdup time (Vout = 12.0V

DC

, Tamb 25C, I

O

=80% I

O, max

)

V

in

= 230V

AC

V

IN

= 100V

AC

T

12

20

ms

Early warning prior to output falling below regulation

1

(Vout = 12.0V

DC

, Tamb 25C, I

O

=80% I

O, max

)

2

Ride through

T

10

Leakage Current (V

IN

= 250V

AC

, F

IN

= 60Hz)

I

IN

3 mA

RMS

Isolation Input/Output

3000

V

AC

Input/Frame

2121

V

DC

Output/Frame

100

V

DC

12V

dc

MAIN OUTPUT

Parameter

Symbol

Min

Typ

Max

Unit

Output Power 180 – 264 / 90-132 Vac

W

0 -

2000/1300

W

V

AC

≤ 90V

AC

0 - 1200 W

Set point

V

O

11.9 12.00 12.1

V

DC

Overall regulation (load, temperature)

-2

+2

%

1

Measured by the DC_OK signal going LO prior to the output decaying below 10.8Vdc

Advertising