GE Industrial Solutions CAR2512TE Front-End User Manual

Car2512te front-end, Preliminary data sheet, Input: 90v

Advertising
background image

GE

Preliminary Data Sheet

February 7, 2014

©2013 General Electric Company. All rights reserved.

CAR2512TE Front-End

Input: 90V

AC

to 264V

AC

; Output: 12V

DC

@ 2500W; 3.3/5V

DC

standby @ 15W

Features

Efficiency meets 80plus ‘Platinum’ requirements

Universal input with PFC

Constant power characteristic

2 front panel LEDs: 1-input;2-[DC_OK, fault, warning]

Remote ON/OFF control of the 12Vdc output

Remote sense on the 12Vdc output

No minimum load requirements

Active load sharing (single wire)

Hot Plug-ability

Standby orderable either as 3.3Vdc or 5Vdc

Auto recoverable OC & OT protection

Operating temperature: -10 - 70C (de-rated above 50C)

Digital status & control: I

2

C and PMBus serial bus

EN/IEC/UL60950-1 2

nd

edition; UL, CSA, VDE , and CCC

EMI: class A FCC docket 20780 part 15, EN55022

Meets EN61000 immunity and transient standards

Shock & vibration: Meets IPC 9592 Class II standards

Applications

12Vdc distributed power architectures

Datacom and Telecom applications

Mid to high-end Servers

Routers/Switches

Broadband Switches

ATE Equipment

Description

The CAR2512TE Front-End provides highly efficient isolated power from worldwide input mains in a compact 1U
industry standard form factor in an unprecedented power density of 25W/in

3

. Ideal for applications where mid to light

load efficiency is of key importance. This front-end is complemented by the CAR2512DC dc/dc converter designed to
convert 48/60Vdc power of telecom central offices. This plug and play approach offers rapid system reconfiguration

by simply replacing the power supply.

The high-density, front-to-back airflow is designed for minimal space utilization and is highly expandable for future

growth. The industry standard PMBus compliant I

2

C communications buss offers a full range of control and

monitoring capabilities. The SMBAlert signal pin alerts customers automatically of any state change within the power

supply.

*

UL is a registered trademark of Underwriters Laboratories, Inc.

CSA is a registered trademark of Canadian Standards Association.

VDE is a trademark of Verband Deutscher Elektrotechniker e.V.

§

Intended for integration into end-user equipment. All the required procedures for CE marking of end-user equipment should be followed. (The CE mark is placed on selected products.)

** ISO is a registered trademark of the International Organization of Standards.
+ PMBus name and logo are registered trademarks of the System Management Interface Forum (SMIF)

Advertising