Preliminary Data Sheet

CAR2512TE Front-End

Input: 90V

AC

to 264V

AC

; Output: 12 V

DC

@ 2500W; 3.3/5V

DC

standby @ 15W

February 7, 2014

©2013 General Electric Company. All rights reserved.

Page 5

Feature Specifications (continued)

Parameter

Symbol

Min

Typ

Max

Unit

SMBAlert# (Interrupt) (pulled up internally via 10kΩ to 3.3V)

i t )

Logic High (No Alert - normal)

V

OH

2.1

3.5 V

DC

Logic Low (Alert is set)

I

OL

20 mA

V

OL

0

0.4 V

DC

Current monitor (Imon) Resolution

15

mV/A

Measurement range

I

OUT

0 208

A

DC

Measurement accuracy, load > 25% of FL, V

O

= 12V

DC

-5

+5

%

of

FL

Analog output range

V

mon

0 3.3

V

DC

Sourced output current

I

OUT

5

mA

DC

Digital Interface Specifications

Parameter

Conditions

Symbol

Min

Typ

Max

Unit

PMBus Signal Interface Characteristics
Input Logic High Voltage (CLK, DATA)

V

IH

2.1 3.6

V

Input Logic Low Voltage (CLK, DATA)

V

IL

0 0.8 V

Input high sourced current (CLK, DATA)

I

IH

0 10 μA

Output Low sink Voltage (CLK, DATA, SMBALERT#)

I

OUT

=3.5mA V

OL

0.4 V

Output Low sink current (CLK, DATA, SMBALERT#)

I

OL

3.5

mA

Output High open drain leakage current (CLK,DATA,
SMBALERT#)

V

OUT

=3.6V I

OH

0 10 μA

PMBus Operating frequency range

Slave Mode

F

PMB

10 400 kHz

Digital Interface Specifications (continued)

Parameter

Type

Symbol

Min

Typ

Max

Unit

Measurement System Characteristics

Clock stretching

t

STRETCH

25

ms

I

OUT

measurement range

Linear

I

RNG

0 210 A

I

OUT

measurement accuracy 25°C

I

ACC

-5 +5 %

V

OUT

measurement range

Linear

V

OUT(rng)

0 14 V

DC

V

OUT

measurement accuracy

V

OUT(acc)

-5 +5 %

Temp measurement range

Linear

Temp

(rng)

0 120

C

Temp measurement accuracy

4

Temp

(acc)

-5 +5 %

I

IN

measurement range

Linear

I

IN(rng)

0 40 A

AC

I

IN

measurement accuracy

I

IN(acc)

-5 +5 %

V

IN

measurement range

Linear

V

IN(rng)

0 300 V

AC

V

IN

measurement accuracy

V

IN(acc)

-5 +5 %

P

IN

measurement range

Linear

P

N(rng)

0 3000 W

P

IN

measurement accuracy

P

IN(acc)

-5 +5 %

Fan Speed measurement range

Linear

0 30k RPM

Fan Speed measurement accuracy

-10 10 %

Fan speed control range

Linear

0 100 %

4

Temperature accuracy reduces non-linearly with decreasing temperature