Ge energy, 2a dlynx, Non-isolated dc-dc power modules – GE Industrial Solutions 2A DLynx User Manual

Page 13: Datasheet, Safety considerations

Advertising
background image

GE Energy

Datasheet

2A DLynx

TM

: Non-Isolated DC-DC Power Modules

3Vdc –14Vdc input; 0.6Vdc to 5.5Vdc output; 2A Output Current


June 24, 2013

©2012 General Electric Company. All rights reserved.

Page 13

Output Filtering

The 12V DLynx

TM

2A modules are designed for low output ripple

voltage and will meet the maximum output ripple specification
with 0.1 µF ceramic and 22µF ceramic capacitors at the output
of the module. However, additional output filtering may be
required by the system designer for a number of reasons. First,

there may be a need to further reduce the output ripple and
noise of the module. Second, the dynamic response
characteristics may need to be customized to a particular load

step change.

To reduce the output ripple and improve the dynamic response

to a step load change, additional capacitance at the output can
be used. Low ESR polymer and ceramic capacitors are
recommended to improve the dynamic response of the

module. A minimum 22uF External Cap must be used. Figure
42 provides output ripple information for different external

capacitance values at various Vo and for a load current of 2A.
For stable operation of the module, limit the capacitance to less
than the maximum output capacitance as specified in the

electrical specification table. Optimal performance of the
module can be achieved by using the Tunable Loop

TM

feature

described later in this data sheet.

0

2

4

6

8

10

12

14

0.5

1.5

2.5

3.5

4.5

Output Voltage(Volts)

Ri

p

p

le

(m

V

p

-p

)

1x22uF External Cap
1x47uF External Cap
2x47uF External cap

Figure 42. Output ripple voltage for various output voltages
with external 1x22 µF, 1x47 µF or 2x47 µF ceramic capacitors

at the output (2A load). Input voltage is 12V.

Safety Considerations

For safety agency approval the power module must be
installed in compliance with the spacing and separation
requirements of the end-use safety agency standards, i.e., UL
60950-1 2nd, CSA C22.2 No. 60950-1-07, DIN EN 60950-1:2006
+ A11 (VDE0805 Teil 1 + A11):2009-11; EN 60950-1:2006 +
A11:2009-03.

For the converter output to be considered meeting the
requirements of safety extra-low voltage (SELV), the input must
meet SELV requirements. The power module has extra-low
voltage (ELV) outputs when all inputs are ELV.

The input to these units is to be provided with a slow-

blow fuse with a maximum rating of 4A in the positive
input lead

.