Datasheet

2A DLynx

TM

: Non-Isolated DC-DC Power Modules

3Vdc –14Vdc input; 0.6Vdc to 5.5Vdc output; 2A Output Current

June 24, 2013

©2012 General Electric Company. All rights reserved.

Page 16

Monotonic Start-up and Shutdown

The 12V DLynx

TM

2A

modules have monotonic start-up and

shutdown behavior for any combination of rated input voltage,
output current and operating temperature range.

Startup into Pre-biased Output

The 12V DLynx

TM

2A modules can start into a prebiased output

as long as the prebias voltage is 0.5V less than the set output
voltage.

Power Good

The 12V DLynx

TM

2A

modules provide a Power Good (PGOOD)

signal that is implemented with an open-drain output to
indicate that the output voltage is within the regulation limits of
the power module. The PGOOD signal will be de-asserted to a

low state if any condition such as overtemperature, overcurrent
or loss of regulation occurs that would result in the output

voltage going ±12.5% outside the setpoint value. The PGOOD
terminal should be connected through a pullup resistor
(suggested value 100K

Ω) to a source of 5VDC or lower.

Tunable Loop

TM

The 12V DLynx

TM

2A modules have a new feature that

optimizes transient response of the module called Tunable
Loop

TM

.

External capacitors are usually added to the output of the
module for two reasons: to reduce output ripple and noise (see
Fig. 42) and to reduce output voltage deviations from the

steady-state value in the presence of dynamic load current
changes. Adding external capacitance however affects the

voltage control loop of the module, typically causing the loop to
slow down with sluggish response. Larger values of external
capacitance could also cause the module to become unstable.

The Tunable Loop

TM

allows the user to externally adjust the

voltage control loop to match the filter network connected to
the output of the module. The Tunable Loop

TM

is implemented

by connecting a series R-C between the SENSE and TRIM pins of
the module, as shown in Fig. 48. This R-C allows the user to
externally adjust the voltage loop feedback compensation of

the module.

MODULE

VOUT

SENSE

TRIM

GND

RTUNE

CTUNE

RTrim

C O

Figure. 48. Circuit diagram showing connection of R

TUME

and

C

TUNE

to tune the control loop of the module.


Recommended values of R

TUNE

and C

TUNE

for different

output capacitor combinations are given in Tables 2 and
3. Table 2 shows the recommended values of R

TUNE

and

C

TUNE

for different values of ceramic output capacitors up

to 470uF that might be needed for an application to
meet output ripple and noise requirements. Selecting
R

TUNE

and C

TUNE

according to Table 2 will ensure stable

operation of the module.

In applications with tight output voltage limits in the
presence of dynamic current loading, additional output

capacitance will be required. Tables 3,4 and 5 list
recommended values of R

TUNE

and C

TUNE

in order to meet

2% output voltage deviation limits for some common

output voltages in the presence of a 1A to 2A step
change (50% of full load), for input voltages of 12V, 5V
and 3.3V respectively.


Please contact your GE Energy technical representative

to obtain more details of this feature as well as for
guidelines on how to select the right value of external R-
C to tune the module for best transient performance and

stable operation for other output capacitance values or
input voltages other than 12V.


Table 2. General recommended values of of R

TUNE

and

C

TUNE

for Vin=12V/5V/3.3V and various external

ceramic capacitor combinations.

Co

1x47

μF 2x47μF 3x47μF 4x47μF 10x47μF

R

TUNE

220 150 100 100 100

C

TUNE

3900pF

10nF 18nF 18nF 22nF



Table 3. Recommended values of R

TUNE

and C

TUNE

to

obtain transient deviation of

2% of Vout for a 1A step

load with Vin=12V

Vo

5V

3.3V

2.5V

1.8V

1.2V

0.6V

Co 1x22μF 1x47μF 2x47μF 2x47μF 3x47μF 330μF

Polymer

R

TUNE

220 220 150 150 100 100

C

TUNE

2200pF 3900pF

10nF 10nF 18nF 68nF

ΔV 81mV 61mV 35mV 34mV 23mV 12mV


Table 4. Recommended values of R

TUNE

and C

TUNE

to

obtain transient deviation of

2% of Vout for a 1A step

load with Vin=5V

Vo

3.3V

2.5V

1.8V

1.2V

0.6V

Co 1x47μF 2x47μF 2x47μF 3x47μF 330μF

Polymer

R

TUNE

220 150 150 100 100

C

TUNE

3900pF

10nF 10nF 18nF 68nF

ΔV

62mV 35mV 34mV 23mV 12mV


Advertising