GE Energy

Datasheet

2A DLynx

TM

: Non-Isolated DC-DC Power Modules

3Vdc –14Vdc input; 0.6Vdc to 5.5Vdc output; 2A Output Current


June 24, 2013

©2012 General Electric Company. All rights reserved.

Page 17

Table 5. Recommended values of R

TUNE

and C

TUNE

to obtain

transient deviation of

2% of Vout for a 1A step load with

Vin=3.3V

Vo

2.5V

1.8V

1.2V

0.6V

Co

3x47

μF 2x47μF 3x47μF

330

μF

Polymer

R

TUNE

100 150 100 100

C

TUNE

18nF 10nF 18nF 68nF

ΔV

48mV 34mV 23mV 12mV

Advertising