Ge energy, 2a dlynx, Non-isolated dc-dc power modules – GE Industrial Solutions 2A DLynx User Manual

Page 5: Datasheet, Feature specifications (cont.)

Advertising
background image

GE Energy

Datasheet

2A DLynx

TM

: Non-Isolated DC-DC Power Modules

3Vdc –14Vdc input; 0.6Vdc to 5.5Vdc output; 2A Output Current


June 24, 2013

©2012 General Electric Company. All rights reserved.

Page 5

Feature Specifications (cont.)

Parameter

Device

Symbol

Min

Typ

Max

Units

Input Undervoltage Lockout

Turn-on Threshold

All

2.95

Vdc

Turn-off Threshold

All

2.8

Vdc

Hysteresis All

0.2 Vdc

PGOOD (Power Good)

Signal Interface Open Drain, V

supply

≤ 5VDC

Overvoltage threshold for PGOOD

112.5 %V

O, set

Undervoltage threshold for PGOOD

87.5 %V

O, set

Pulldown resistance of PGOOD pin

All

30 70 Ω