40A Digital MegaDLynx

TM

: Non-Isolated DC-DC Power Modules

4.5Vdc –14.4Vdc input; 0.45Vdc to 2.0Vdc output; 40A Output Current

April 24, 2013

©2012 General Electric Company. All rights reserved.

Page 17

PU: Sets the default to either operate any time input power is
present or for the ON/OFF to be controlled by the analog
ON/OFF input and the PMBus OPERATION command. This bit
is used together with the CP, CMD and ON bits to determine
startup.

Bit Value

Action

0

Module powers up any time power is present
regardless of state of the analog ON/OFF pin

1

Module does not power up until commanded
by the analog ON/OFF pin and the
OPERATION command as programmed in
bits [2:0] of the ON_OFF_CONFIG register.

CMD: The CMD bit controls how the device responds to the
OPERATION command.

Bit Value

Action

0

Module ignores the ON bit in the OPERATION
command

1

Module responds to the ON bit in the
OPERATION command

CPR: Sets the response of the analog ON/OFF pin. This bit is
used together with the CMD, PU and ON bits to determine
startup.

Bit Value

Action

0

Module ignores the analog ON/OFF pin, i.e.
ON/OFF is only controlled through the
PMBUS via the OPERATION command

1

Module requires the analog ON/OFF pin to be
asserted to start the unit

PMBus Adjustable Soft Start Rise Time

The soft start rise time can be adjusted in the module via
PMBus. When setting this parameter, make sure that the
charging current for output capacitors can be delivered by
the module in addition to any load current to avoid nuisance
tripping of the overcurrent protection circuitry during startup.
The TON_RISE command sets the rise time in ms, and allows
choosing soft start times between 600μs and 9ms, with
possible values listed in Table 5. Note that the exponent is
fixed at -4 (decimal) and the upper two bits of the mantissa
are also fixed at 0.

Table 5

Rise Time

Exponent

Mantissa

600μs

11100

00000001010

900μs

11100

00000001110

1.2ms

11100

00000010011

1.8ms

11100

00000011101

2.7ms

11100

00000101011

4.2ms

11100

00001000011

6.0ms

11100

00001100000

9.0ms

11100

00010010000

Output Voltage Adjustment Using the PMBus

The VOUT_SCALE_LOOP parameter is important for a number
of PMBus commands related to output voltage trimming,
margining, over/under voltage protection and the PGOOD
thresholds. The output voltage of the module is set as the
combination of the voltage divider formed by RTrim and a
20kΩ upper divider resistor inside the module, and the
internal reference voltage of the module. The reference
voltage V

REF

is nominally set at 600mV, and the output

regulation voltage is then given by

REF

OUT

V

RTrim

RTrim

V





20000

Hence the module output voltage is dependent on the value
of RTrim which is connected external to the module. The
information on the output voltage divider ratio is conveyed to
the module through the VOUT_SCALE_LOOP parameter
which is calculated as follows:

RTrim

RTrim

LOOP

SCALE

VOUT

20000

_

_

The VOUT_SCALE_LOOP parameter is specified using the
“Linear” format and two bytes. The upper five bits [7:3] of the
high byte are used to set the exponent which is fixed at –9
(decimal). The remaining three bits of the high byte [2:0] and
the eight bits of the lower byte are used for the mantissa. The
default value of the mantissa is 00100000000 corresponding
to 256 (decimal), corresponding to a divider ratio of 0.5. The
maximum value of the mantissa is 512 corresponding to a
divider ratio of 1. Note that the resolution of the
VOUT_SCALE_LOOP command is 0.2%.

When PMBus commands are used to trim or margin the
output voltage, the value of V

REF

is what is changed inside the

module, which in turn changes the regulated output voltage
of the module.

The nominal output voltage of the module can be adjusted
with a minimum step size of 0.4% over a ±25% range from
nominal using the VOUT_TRIM command over the PMBus.

The VOUT_TRIM command is used to apply a fixed offset
voltage to the output voltage command value using the
“Linear” mode with the exponent fixed at –10 (decimal). The
value of the offset voltage is given by

10

)

(

2

_

TRIM

VOUT

V

offset

OUT

This offset voltage is added to the voltage set through the
divider ratio and nominal V

REF

to produce the trimmed output

voltage. The valid range in two’s complement for this
command is –4000h to 3999h. The high order two bits of
the high byte must both be either 0 or 1. If a value outside of
the +/-25% adjustment range is given with this command,
the module will set its output voltage to the nominal value (as
if VOUT_TRIM had been set to 0), assert SMBALRT#, set the
CML bit in STATUS_BYTE and the invalid data bit in
STATUS_CML.