40a digital megadlynx, Non-isolated dc-dc power modules, Data sheet – GE Industrial Solutions 40A Digital MegaDLynx User Manual

Page 25

Advertising
background image

GE

Data Sheet

40A Digital MegaDLynx

TM

: Non-Isolated DC-DC Power Modules

4.5Vdc –14.4Vdc input; 0.45Vdc to 2.0Vdc output; 40A Output Current

April 24, 2013

©2012 General Electric Company. All rights reserved.

Page 25

Table 6 (continued)

Hex

Code

Command

Brief Description

Non-Volatile

Memory Storage

44

VOUT_UV_FAULT_LIMIT

Sets the voltage level for an output undervoltage fault. Exponent is fixed at -10.

Format

Linear, two’s complement binary

Bit Position

7

6

5

4

3

2

1

0

Access

r

r/w

r/w

r/w

r/w

r/w

r/w

r/w

Function

High Byte

Default Value

0

0

0

0

0

1

0

0

Bit Position

7

6

5

4

3

2

1

0

Access

r/w

r/w

r/w

r/w

r/w

r/w

r/w

r/w

Function

Low Byte

Default Value

1

0

0

0

1

1

1

1

YES

45

VOUT_UV_FAULT_RESPONSE

Instructs the module on what action to take in response to a output undervoltage
fault

Format

Unsigned Binary

Bit Position

7

6

5

4

3

2

1

0

Access

r/w

r/w

r/w

r/w

r/w

r

r

r

Function

RSP

[1]

RSP

[0]

RS[2] RS[1] RS[0]

X

X

X

Default Value

0

0

0

0

0

1

0

0

YES

46

IOUT_OC_FAULT_LIMIT

Sets the output overcurrent fault level in A (cannot be changed)

Format

Linear, two’s complement binary

Bit Position

7

6

5

4

3

2

1

0

Access

r

r

r

r

r

r

r

r

Function

Exponent

Mantissa

Default Value

1

1

1

1

1

0

0

0

Bit Position

7

6

5

4

3

2

1

0

Access

r

r

r

r

r

r

r

r

Function

Mantissa

Default Value

0

1

1

1

0

1

0

0

YES

4A

IOUT_OC_WARN_LIMIT

Sets the output overcurrent warning level in A

Format

Linear, two’s complement binary

Bit Position

7

6

5

4

3

2

1

0

Access

r

r

r

r

r

r

r

r

Function

Exponent

Mantissa

Default Value

1

1

1

1

1

0

0

0

Bit Position

7

6

5

4

3

2

1

0

Access

r

r/w

r/w

r/w

r/w

r/w

r/w

r/w

Function

Mantissa

Default Value

0

1

1

1

0

0

1

0

YES

5E

POWER_GOOD_ON

Sets the output voltage level at which the PGOOD pin is asserted high. Exponent is
fixed at -10.

Format

Linear, two’s complement binary

Bit Position

7

6

5

4

3

2

1

0

Access

r

r/w

r/w

r/w

r/w

r/w

r/w

r/w

Function

High Byte

Default Value

0

0

0

0

0

1

0

0

Bit Position

7

6

5

4

3

2

1

0

Access

r/w

r/w

r/w

r/w

r/w

r/w

r/w

r/w

Function

Low Byte

Default Value

0

1

1

0

1

0

1

0

YES

Advertising