40a digital megadlynx, Non-isolated dc-dc power modules, Data sheet – GE Industrial Solutions 40A Digital MegaDLynx User Manual

Page 5: Feature specifications (cont.)

Advertising
background image

GE

Data Sheet

40A Digital MegaDLynx

TM

: Non-Isolated DC-DC Power Modules

4.5Vdc –14.4Vdc input; 0.45Vdc to 2.0Vdc output; 40A Output Current

April 24, 2013

©2012 General Electric Company. All rights reserved.

Page 5

Feature Specifications (cont.)

Parameter

Device

Symbol

Min

Typ

Max

Units

Over Temperature Protection
(See Thermal Considerations section)

All

T

ref

145

°C

PMBus Over Temperature Warning Threshold*

All

T

WARN

130

°C

Tracking Accuracy (Power-Up: 0.5V/ms)

All

V

SEQ

–V

o

100

mV

(Power-Down: 0.5V/ms)

All

V

SEQ

–V

o

100

mV

(V

IN, min

to V

IN, max

; I

O, min

to I

O, max

V

SEQ

< V

o

)

Input Undervoltage Lockout

Turn-on Threshold

All

4.25

Vdc

Turn-off Threshold

All

3.96

Vdc

Hysteresis

All

0.25

Vdc

PMBus Adjustable Input Under Voltage Lockout
Thresholds

All

2.5

14

Vdc

Resolution of Adjustable Input Under Voltage Threshold

All

500

mV

PGOOD (Power Good)

Signal Interface Open Drain, V

supply

5VDC

Overvoltage threshold for PGOOD ON

All

108

%V

O, set

Overvoltage threshold for PGOOD OFF

All

110

%V

O, set

Undervoltage threshold for PGOOD ON

All

92

%V

O, set

Undervoltage threshold for PGOOD OFF

All

90

%V

O, set

Pulldown resistance of PGOOD pin

All

50

Sink current capability into PGOOD pin

All

5

mA

* Over temperature Warning – Warning may not activate before alarm and unit may shutdown before warning.