40a digital megadlynx, Non-isolated dc-dc power modules, Data sheet – GE Industrial Solutions 40A Digital MegaDLynx User Manual

Page 22: Summary of supported pmbus commands

Advertising
background image

GE

Data Sheet

40A Digital MegaDLynx

TM

: Non-Isolated DC-DC Power Modules

4.5Vdc –14.4Vdc input; 0.45Vdc to 2.0Vdc output; 40A Output Current

April 24, 2013

©2012 General Electric Company. All rights reserved.

Page 22

Summary of Supported PMBus Commands

Please refer to the PMBus 1.1 specification for more details of these commands.

Table 6

Hex

Code

Command

Brief Description

Non-Volatile

Memory Storage

01

OPERATION

Turn Module on or off. Also used to margin the output voltage

Format

Unsigned Binary

Bit Position

7

6

5

4

3

2

1

0

Access

r/w

r

r/w

r/w

r/w

r/w

r

r

Function

On

X

Margin

X

X

Default Value

0

0

0

0

0

0

X

X

02

ON_OFF_CONFIG

Configures the ON/OFF functionality as a combination of analog ON/OFF pin and
PMBus commands

Format

Unsigned Binary

Bit Position

7

6

5

4

3

2

1

0

Access

r

r

r

r/w

r/w

r/w

r/w

r

Function

X

X

X

pu

cmd

cpr

pol

cpa

Default Value

0

0

0

1

0

1

1

1

YES

03

CLEAR_FAULTS

Clear any fault bits that may have been set, also releases the SMBALERT# signal if
the device has been asserting it.

10

WRITE_PROTECT

Used to control writing to the module via PMBus. Copies the current register setting
in the module whose command code matches the value in the data byte into non-
volatile memory (EEPROM) on the module

Format

Unsigned Binary

Bit Position

7

6

5

4

3

2

1

0

Access

r/w

r/w

r/w

x

x

x

x

x

Function

bit7

bit6

bit5

X

X

X

X

X

Default Value

0

0

0

X

X

X

X

X

Bit5: 0 – Enables all writes as permitted in bit6 or bit7
1 – Disables all writes except the WRITE_PROTECT, OPERATION
and ON_OFF_CONFIG (bit 6 and bit7 must be 0)
Bit 6: 0 – Enables all writes as permitted in bit5 or bit7
1 – Disables all writes except for the WRITE_PROTECT and
OPERATION commands (bit5 and bit7 must be 0)
Bit7: 0 – Enables all writes as permitted in bit5 or bit6
1 – Disables all writes except for the WRITE_PROTECT command
(bit5 and bit6 must be 0)

YES

11

STORE_DEFAULT_ALL

Copies all current register settings in the module into non-volatile memory
(EEPROM) on the module. Takes about 50ms for the command to execute.

12

RESTORE_DEFAULT_ALL

Restores all current register settings in the module from values in the module non-
volatile memory (EEPROM)

13

STORE_DEFAULT_CODE

Copies the current register setting in the module whose command code matches
the value in the data byte into non-volatile memory (EEPROM) on the module

Bit Position

7

6

5

4

3

2

1

0

Access

w

w

w

w

w

w

w

w

Function

Command code

14

RESTORE_DEFAULT_CODE

Restores the current register setting in the module whose command code matches
the value in the data byte from the value in the module non-volatile memory
(EEPROM)

Bit Position

7

6

5

4

3

2

1

0

Access

w

w

w

w

w

w

w

w

Function

Command code

20

VOUT_MODE

The module has MODE set to Linear and Exponent set to -10. These values cannot
be changed

Bit Position

7

6

5

4

3

2

1

0

Access

r

r

r

r

r

r

r

r

Function

Mode

Exponent

Default Value

0

0

0

1

0

1

1

0