40a digital megadlynx, Non-isolated dc-dc power modules, Data sheet – GE Industrial Solutions 40A Digital MegaDLynx User Manual

Page 6: Digital interface specifications

Advertising
background image

GE

Data Sheet

40A Digital MegaDLynx

TM

: Non-Isolated DC-DC Power Modules

4.5Vdc –14.4Vdc input; 0.45Vdc to 2.0Vdc output; 40A Output Current

April 24, 2013

©2012 General Electric Company. All rights reserved.

Page 6

Digital Interface Specifications

Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and temperature conditions. See
Feature Descriptions for additional information.

Parameter

Conditions

Symbol

Min

Typ

Max

Unit

PMBus Signal Interface Characteristics

Input High Voltage (CLK, DATA)

V

IH

2.1

3.6

V

Input Low Voltage (CLK, DATA)

V

IL

0.8

V

Input high level current (CLK, DATA)

I

IH

-10

10

μA

Input low level current (CLK, DATA)

I

IL

-10

10

μA

Output Low Voltage (CLK, DATA, SMBALERT#)

I

OUT

=2mA

V

OL

0.4

V

Output high level open drain leakage current (DATA,
SMBALERT#)

V

OUT

=3.6V

I

OH

0

10

μA

Pin capacitance

C

O

0.7

pF

PMBus Operating frequency range

Slave Mode

F

PMB

10

400

kHz

Data hold time

Receive Mode

Transmit Mode

t

HD:DAT

0

300

ns

Data setup time

t

SU:DAT

250

ns

Measurement System Characteristics

Read delay time

t

DLY

153

192

231

μs

Output current measurement range

I

RNG

0

40

A

Output current measurement resolution

I

RES

62.5

mA

Output current measurement gain accuracy (at 25°C)

I

ACC

±5

%

Output current measurement offset

I

OFST

0.1

A

V

OUT

measurement range

V

OUT(rng)

0

2.0

V

V

OUT

measurement resolution

V

OUT(res)

16.25

mV

V

OUT

measurement gain accuracy

V

OUT(gain)

-2

2

LSB

V

OUT

measurement offset

V

OUT(ofst)

-3

3

LSB

V

OUT

measurement accuracy

70

mV

V

IN

measurement range

V

IN(rng)

0

14.4

V

V

IN

measurement resolution

V

IN(res)

32.5

mV

V

IN

measurement gain accuracy

V

IN(gain)

-2

2

LSB

V

IN

measurement offset

V

IN(ofst)

-5.5

1.4

%

V

IN

measurement accuracy

V

IN

±3

%

Advertising