GEI-100350A

—————— TECHNICAL DATA ——————

3

4

Regulation board terminal strips:

Terminals

Name

Function

I/Q

Volt. max.

Curr. max.

1

+24V

Supply for commands TIM-RESET

Q

24V

200mA

2

0V 24V

0V potential of the +24V supply

3

TIM

Connection for the thermal contact of
resistor protection

I

15...30V

3.2...6.4 mA

4

RESET

Remote Reset of alarm condition

I

15...30V

3.2...6.4 mA

5

MCMD

Slave unit command (Master output)

Q

24V ± 5%

30 mA

6

0V 24V

0V potential of MCMD command

7

SIN

Slave unit input command

I

8...30V

16 mA

8

SIN

Slave unit input command

I

8...30V

16 mA

9

SOUT

Cascade connection of Slave units

Q

8...30V

16 mA

10

SOUT

Cascade connection of Slave units

Q

8...30V

16 mA

75

OK

OK relay dry contact (closed = OK)

Q

250Vca

1 A

76

OK

OK relay dry contact (closed = OK)

Q

250Vca

1 A

bu0030

Maximum cable sizes for power terminals C,D,CR,BR

Braking Unit type

Maximum Permissible Cable Cross-Section

[mm

2

]

flexible

multi-core

6KBU300-20

10

10

12

6KBU300-50

16

16

10

6KBU300-85

35

35

2

bu0031

AWG

Maximum cable sizes of the regulation section terminals

Terminals

Maximum Permissible Cable Cross-Section

[mm

2

]

flexible

multi-core

1 ... 76

0.35 ... 1.5

0.35 ... 1.5

22 ... 16

bu0032

AWG