2. MAINS CHARACTERISTICS

-

Protection IP20

-

Max. working temperature 40°C (104°F) ambient (max 50°C (122°F) with a 20% of derating)

-

Costant switching on time (max. time ON) 3 minutes

-

Max.duty cycle admitted 50%

-

Supply of the circuit obtained by the DC Link

-

Possibility of parallel connection up to 3 units managed by a “MASTER” unit (4 slave units managed by a
drive set as master)

-

DC Bus threshold set by dip switches

-

Signaling of the +24V supply presence (Green diode led +24V)

-

Signaling of the Brake unit activity (Yellow diode led BR)

-

Signaling of alarm condition AL (Red diode led AL)

-

Signaling of OK condition (Green diode led OK)

-

OK relay dry contacts available for alarm sequences

-

Input to connect a resistor mounted klixon contact

-

Possibility of quick discharge of the DC Link.