Summary of Supported PMBus Commands

Please refer to the PMBus 1.1 specification for more details of these commands.

Table 6

Hex

Code

Command

Brief Description

Non-Volatile

Memory Storage

00 PAGE

Ability to configure, control and monitor each output by using only one physical
address of the module

Format

Unsigned Binary

Bit Position

7 6 5 4 3 2 1 0

Access

r/w r r

r

r

r

r r/w

Function

PA X X X X X X P0

Default Value

0 X X X X X X 0

PAGE Command Truth Table

PA

P0

Logic Results

0 0

All Commands address first output

0 1

All Commands address second output

1 0

Illegal input, Ignore write

1 1

All Commands address both outputs

01 OPERATION

Turn Module on or off. Also used to margin the output voltage

Format

Unsigned Binary

Bit Position

7 6 5 4 3 2 1 0

Access

r/w r r/w

r/w

r/w

r/w

r r

Function

On X

Margin

X X

Default Value

0 0 0 0 0 0 X X

Bit 7: 0 Output switching disabled

1

Output switching enabled

Margin: 00XX Margin Off
0101 Margin Low ( Act on fault)
0110 Margin Low (Act on fault)
1001 Margin High (Act on fault)

1010 Margin High (Act on fault)

02 ON_OFF_CONFIG

Configures the ON/OFF functionality as a combination of analog ON/OFF pin

and PMBus commands

Format

Unsigned Binary

Bit Position

7 6 5 4 3 2 1 0

Access

r r r

r/w

r/w

r/w

r/w r

Function

X X X pu

cmd

cpr

pol

cpa

Default Value

0 0 0 1 0 1 1 0

Refer to Page 19 for details on pu, cmd, cpr, pol and cpa

YES

03 CLEAR_FAULTS

Clear any fault bits that may have been set, also releases the SMBALERT# signal

if the device has been asserting it.

10 WRITE_PROTECT

Used to control writing to the module via PMBus. Copies the current register
setting in the module whose command code matches the value in the data byte
into non-volatile memory (EEPROM) on the module

Format

Unsigned Binary

Bit Position

7 6 5 4 3 2 1 0

Access

r/w r/w r/w

x

x

x

x x

Function

bit7

bit6

bit5 X X X X X

Default Value

0 0 0 X X X X X

Bit5: 0 – Enables all writes as permitted in bit6 or bit7
1 – Disables all writes except the WRITE_PROTECT, PAGE OPERATION
and ON_OFF_CONFIG (bit 6 and bit7 must be 0)
Bit 6: 0 – Enables all writes as permitted in bit5 or bit7

1 – Disables all writes except for the WRITE_PROTECT, PAGE and

OPERATION commands (bit5 and bit7 must be 0)
Bit7: 0 – Enables all writes as permitted in bit5 or bit6
1 – Disables all writes except for the WRITE_PROTECT command
(bit5 and bit6 must be 0)

YES

15 STORE_USER_ALL

Stores all of the current storable register settings in the EEPROM memory as the
new defaults on power up