2 × 12a digital dual microdlynx, Non-isolated dc-dc power modules, Datasheet – GE Industrial Solutions 2 × 12A Digital Dual Output MicroDLynx User Manual

Page 27

Advertising
background image

GE

Datasheet

2 × 12A Digital Dual MicroDlynx

TM

: Non-Isolated DC-DC Power Modules

4.5Vdc –14.4Vdc input; 0.51Vdc to 5.5Vdc output; 2 × 12A Output Current

February 14, 2014

©2014 General Electric Corporation. All rights reserved.

Page 27


Hex

Code

Command

Brief Description

Non-Volatile

Memory Storage

7B STATUS_IOUT

Returns one byte of information with the status of the module’s output current related

faults

Format

Unsigned Binary

Bit Position

7

6

5

4 3 2 1 0

Access

r r r

r

r

r

r r

Flag

IOUT_OC Fault X

IOUT OC Warning

X

X

X X X

Default Value

0

0

0

0 0 0 0 0

7D STATUS_TEMPERATURE

Returns one byte of information with the status of the module’s temperature related
faults

Format

Unsigned Binary

Bit Position

7

6

5 4 3 2 1 0

Access

r r

r

r

r

r

r r

Flag

OT_FAULT OT_WARN X X X X X X

Default Value

0

0

0 0 0 0 0 0

7E STATUS_CML

Returns one byte of information with the status of the module’s communication related

faults

Format

Unsigned Binary

Bit Position

7 6

5

4

3

2 1 0

Access

r r

r

r

r

r

r r

Flag

Invalid

Command

Invalid

Data

PEC

Fail

Memory

fault

detected

X X

Other

Comm

Fault

X

Default Value

0 0

0

0

0

0 0 0

80 STATUS_MFR_SPECIFIC

Returns one byte of information with the status of the module specific faults or warning

Format

Unsigned Binary

Bit Position

7 6 5 4 3 2

1

0

Access

r r r

r

r

r

r R

Flag

OTFI

x X

IVADDR

X X

X TWOPH_EN

Default Value

0 0 0 0 0 0

0

0

OTFI – Internal Temperature above Thermal Shutdown threshold
IVADDR – PMBUs address is not valid
TWOPH_EN – Module is in 2 phase mode

8B READ_VOUT

Returns the value of the output voltage of the module. Exponent is fixed at -9.

Format

Linear, two’s complement binary

Bit Position

7 6 5 4 3 2 1 0

Access

r r r

r

r

r

r r

Function

Mantissa

Default Value

0 0 0 0 0 0 0 0

Bit Position

7 6 5 4 3 2 1 0

Access

r r r

r

r

r

r r

Function

Mantissa

Default Value

0 0 0 0 0 0 0 0

8C READ_IOUT

Returns the value of the output current of the module

Format

Linear, two’s complement binary

Bit Position

7 6 5 4 3 2 1 0

Access

r r r

r

R

r

r r

Function

Exponent Mantissa

Default Value

1 1 1 0 0 V V V

Bit Position

7 6 5 4 3 2 1 0

Access

r r r

r

r

r

r r

Function

Mantissa

Default Value

V V V V V V V 0

V - Variable

Advertising