2 × 12a digital dual microdlynx, Non-isolated dc-dc power modules, Datasheet – GE Industrial Solutions 2 × 12A Digital Dual Output MicroDLynx User Manual

Page 26

Advertising
background image

GE

Datasheet

2 × 12A Digital Dual MicroDlynx

TM

: Non-Isolated DC-DC Power Modules

4.5Vdc –14.4Vdc input; 0.51Vdc to 5.5Vdc output; 2 × 12AOutput Current

February 14, 2014

©2014 General Electric Corporation. All rights reserved.

Page 26


Hex

Code

Command

Brief Description

Non-Volatile

Memory Storage

4F



OT_FAULT_LIMIT



Value may be locked

Sets the overtemperature fault level in °C

Format

Linear, two’s complement binary

Bit Position

7 6 5 4 3 2 1 0

Access

r r r

r

r

r

r r

Function

Exponent Mantissa

Default Value

0 0 0 0 0 0 0 0

Bit Position

7 6 5 4 3 2 1 0

Access

r/w r/w r/w

r/w

r/w

r/w

r/w r/w

Function

Mantissa

Default Value

1 0 0 0 0 1 1 1

YES

51




OT_WARN_LIMIT



Value may be locked

Sets the over temperature warning level in °C

Format

Linear, two’s complement binary

Bit Position

7 6 5 4 3 2 1 0

Access

r r r

r

r

r

r r

Function

Exponent Mantissa

Default Value

0 0 0 0 0 0 0 0

Bit Position

7 6 5 4 3 2 1 0

Access

r/w r/w r/w

r/w

r/w

r/w

r/w r/w

Function

Mantissa

Default Value

0 1 1 1 1 1 0 1

YES

61 TON_RISE

Sets the rise time of the output voltage during startup.
Supported Values – 0.6, 0.9, 1.2, 1.8, 2.7, 4.2, 6.0, 9.0msec. Value of 0 instructs unit to

bring its output to programmed value as quickly as possible

Format

Linear, two’s complement binary

Bit Position

7 6 5 4 3 2 1 0

Access

r r r

r

r

r

r r/w

Function

Exponent Mantissa

Default Value

1 1 1 0 0 0 0 0

Bit Position

7 6 5 4 3 2 1 0

Access

r/w r/w r/w

r/w

r/w

r/w

r/w r/w

Function

Mantissa

Default Value

0 0 1 0 1 0 1 1

YES

78 STATUS_BYTE

Returns one byte of information with a summary of the most critical module faults

Format

Unsigned Binary

Bit Position

7 6 5 4 3 2 1 0

Access

r r r

r

r

r

r r

Flag

X OFF

VOUT

_OV

IOUT_

OC

VIN_U

V

TEMP CML

None

of the

Above

Default Value

0 0 0 0 0 0 0 0

79 STATUS_WORD

Returns two bytes of information with a summary of the module’s fault/warning
conditions

Format

Unsigned Binary

Bit Position

7 6 5 4 3 2 1 0

Access

r r r

r

r

r

r r

Flag

VOUT IOUT/P

OUT

X MFR

PGOOD

X X X

Default Value

0 0 0 0 0 0 0 0

Bit Position

7 6 5 4 3 2 1 0

Access

r r r

r

r

r

r r

Flag

X OFF VOUT_

OV

IOUT_

OC

VIN_U

V

TEMP CML

None

of the

above

Default Value

0 X 0 0 0 0 0 0

7A STATUS_VOUT

Returns one byte of information with the status of the module’s output voltage related

faults

Format

Unsigned Binary

Bit Position

7 6

5 4 3

2

1

0

Access

r r

r

r

r

r

r r

Flag

VOUT_OV X X VOUT_UV X X X X

Default Value

0 0

0 0 0

0

0

0

Advertising