23

ITEM

NO.

CONTROL

FUNCTION

4

5

Elevation

Adjustment

Screws

Windage

Adjustment

Screws

Adjust the laser(s) boresight.

NOTE:

When turning the screws, adjustment mechanisms

click in increments corresponding to the minimum

boresight correction value 0.5 mils (5cm at a

distance of 100m).

The circular scales are indexed in 0.5 mils adjustment

increments.

Elevation and windage adjustment ranges are cov-

ered in approximately 4 turns of the screws.

NOTE:

If using one of the two-channel devices, remember

that the screws adjust the boresight of both lasers

concurrently.

-

Remote Control

Button

Activates/deactivates the laser(s) in standby when

held down/released.

TABLE 3-2. OPERATION MODES

MODEL

OPERATING PARAMETERS

OFF

LOW-POWER OPERATION

HIGH-POWER OPERATION

“LOW 1”

“LOW 2”

“HI 1”

“HI 2”

DRAKOS

Turned off

IR Dot

Level 1

0.1 mW

IR Dot

Level 2

0.2 mW

IR Dot

Level 3

0.3 mW

IR Dot

Level 4

0.7 mW

DRAKOS-I

Turned off

IR Dot

Level 1

0.2 mW

IR Dot

Level 1

0.2 mW &

IR Illum

Level 1

125 mW

IR Dot

Level 2

0.9 mW

IR Dot

Level 2

0.9 mW &

IR Illum

Level 2

250 mW

DRAKOS-II

Turned off

IR Dot

Level 1

0.1 mW

Red Dot

Level 1

0.3 mW

IR Dot

Level 2

0.6 mW

Red Dot

Level 2

0.9 mW

TABLE 3-1. CONTINUED