3.3. OPERATING PROCEDURES

NOTE:
When operating the LAD’s IR channel(s), you must wear night vision

goggles.

CAUTION:
DO NOT force the equipment controls past their stopping points.

3.3.1 BORESIGHT ADJUSTMENT PROCEDURE

NOTE:
Before adjusting the LAD boresight for the first time, fire approximate-

ly 10 shots from the weapon with the device installed, in order to sta-

bilize the adjustment mechanisms under applied shocks.

NOTE:
When adjusting the equipment boresight, beware of reflections from

optical surfaces.

To adjust the boresight:
1. Locate a target at the fire adjustment range (100m).
2. Take aim at the center of the target using the weapon’s iron sight; secure

the weapon in the aiming rest.

3. Unscrew the caps from the adjustment screws.
4. Remove the cap from the output aperture of the aiming laser.
5. Turn the switch to the required position, and activate the LAD (push

ON).

6. Using a screwdriver

To shift the aiming dot to the right, turn the windage adjustment screw

CCW. To shift it to the left, turn the screw CW.
To shift the aiming dot down, turn the elevation adjustment screw

CCW. To shift it up, turn the screw CW.

7. Fire a series of shots.