8. Work out the values of the elevation and windage corrections required

to compensate for the measured deviation of the mean point of impact

(MPI) from the center of the target. The minimum correction value of 0.5

mils (5 cm at a distance of 100 m) corresponds to one click of the adjust-

ment mechanisms.

9. Adjust the equipment boresight by turning the adjustment screws and

counting out a definite number of clicks (or reading the scales).

NOTE:
To shift the MPI to the right, turn the windage adjustment screw CW.

To shift the MPI to the left, turn the screw CCW.
To shift the MPI down, turn the elevation adjustment screw CW. To

shift the MPI up, turn the screw CCW.

10. To check the equipment boresight, use the laser dot to take aim at the

center of the target and fire a series of shots.

11. After completing the boresight adjustment procedure, turn the device

OFF and replace the cap(s) on the laser output aperture(s) and the adjust-

ment screws.

3.3.2 OPERATING PROCEDURE

To operate the LAD:
1. If you are operating the device using high-power levels, use a 2mm hex

key to unscrew the safety lock.

2. Remove the cap(s) from the laser output aperture(s).
3. Turn the switch to the required position.
4. Activate the LAD (push ON).
5. To go to standby, push ON a second time. To activate/deactivate the LAD

while in standby mode, hold down/release the remote control button.

6. To align the barrel of the weapon, center the aiming dot on the desired

target. To allow for the bullet travel (i.e. bullet drop, windage, distance

between the direction of the beam and the axis of the barrel and the tar-

get mobility), use the clicking adjustment mechanisms.

WARNING:

DO NOT leave the LAD activated when it’s not in use.