Armasight IAIR002LP000001 DRAKOS 2 Multi-Spectral Laser Aiming/ Illumination Devices User Manual

Page 29

Advertising
background image

29

SEQ

NO.

LOCATION/

ITEM TO

INSPECT/ CHECK/

SERVICE

PROCEDURE

NOT FULLY MISSION

CAPABLE IF...

OPERATIONAL CHECKS

WARNINGS:

NEVER LOOK INTO THE LASER BEAM.

When performing operational checks, beware of reflections from optical

surfaces.

NOTE:

You must wear NVG when checking IR channel(s).

10 Aiming Laser(s)

Install the battery. Turn the switch

to the position corresponding

to the minimum laser output of

the aiming channel. Push the ON

button down to activate the laser.

Direct the radiated beam at a wall

from a distance of about 5m. A red

(infrared) dot should appear on the

wall. To see an infrared dot, look

through the NVG.

No aiming dot.

11 Remote

Control Unit

Push the ON button down again to

actuate standby mode. Push the

remote control button down to acti-

vate the laser. A red (infrared) dot

should appear on the wall.

No aiming dot.

12 IR Illuminator

Turn the switch to the position

corresponding to the minimum

laser output of the IR illuminator.

Activate the laser. Direct the radi-

ated beam at a wall from a distance

of about 5m. Look through the NVG.

A spot of light should appear on

the wall.

No light appears

on the wall.

13 Boresight

Perform boresight testing as per

Part 4.3.3.

Adjustment

mechanisms are

inoperative.

TABLE 4-1. CONTINUED

Advertising