EDID

Configuration

This section provides information on:

z

z

EDID Configuration Overview

z

z

EDID Configuration Table

EDID Configuration Overview

EDID Minder automatically manages the EDID between a digital display device and one or
more input sources. By maintaining continuous EDID communication with all sources,
EDID Minder ensures that digital sources power up properly and maintain their video output,
whether or not they are actively connected to the digital display device.
EDID Minder is built into this product, which provides EDID to the input source device. The
EDID provided by the HAE 100 forces the source to output the correct audio format.
The EDID can be communicated in two modes:

z

z

Factory default

z

z

User assigned

Factory Default Mode

In factory default mode, a factory default EDID will be used depending on which audio
format is chosen with the Audio Format toggle switch. To communicate the EDID using the
factory default mode, make sure that the EDID Store DIP switch is in the Off (down) position.
For more information on this mode, see the "

EDID Configuration Table

" on the next page.

User Assigned Mode

In user assigned mode, a stored EDID can be used. The EDID can be stored from an output
device (display) connected to the HDMI output. After the EDID has been stored, the EDID
is modified in real time, depending on the particular characteristics of the EDID and the
position of the Audio Format toggle switch. This allows for the proper audio format to be
output from the source. For more information on this mode, see the "

EDID Configuration

Table

" on the next page.

NOTE: Changing the Audio Format toggle switch updates the stored EDID

automatically.