Upgrade Guide, cont’d

Global Configurator, Windows-based Control Programs



PRELIMINAR

Y

Step 2: Apply the Patch.

1.

Using Internet Explorer, browse to the System 5 IP internal Web page by

entering http://x.x.x.x/nortxe_index.html, where x.x.x.x is the IP address used

in step 1.

2.

Select the Configuration tab and then select Firmware Upgrade from the left

side menu as shown below.

3.

Browse to the directory specified during setup. The default location is

C:\Program Files\Extron\Firmware\System_5_IP\Patch

.

4.

Select the patch file 503512V100.S19, then click Upload to initiate the process.

Step : Verify the patch

5.

To verify that the patch is applied to your device, use Telnet (see step 1 on

page 13 for details) and enter the SIS command *Q.

This returns the current firmware version in the following format: x.yy.zzzz where

x.yy

matches the value from step 1, C. on page 13. The value for zzzz should

display as 0007.

N

Telnet may not connect right away because the patch installation and reboot

process take some time to finish. It may be up to 2 minutes before a connection is
complete.

Step : Upgrade the firmware.

You can now load firmware version 2.00.

1.

Select the Configuration tab and then select Firmware Upgrade from the left

side menu.

2.

Browse to the directory specified during setup; the default location is

C:\Program Files\Extron\Firmware\System_5_IP\0x

.

3.

Select the firmware file System_5_IP_19_1335_50_V2_00.S19, then click
Upload

to initiate the process.

N

It may take time for the firmware to load and initialize, so the Web page may not

return right away. This does not indicate a problem; wait 30-45 seconds and
click the
Status tab again.

4.

Once the upload is complete, enter the EscZY reset command via Telnet or

RS-232.

PRELIMINAR

Y

Advertising