Special application, cont’d – Extron Electronics MGP 462D User Manual

Page 110

Advertising
background image

Special Application, cont’d

MGP 462 • Special Application

6-6

Additional setup procedures if using a third party control
system without the MGP Sync tool

When operating the system using a third-party control system, you can prevent the
image from blanking or scrambling on the display during input switches by
performing the following additional setup procedures:

1

.

While setting up the switcher and the MGP to work together, set the RGB

delay on the matrix switcher to greater than, or equal to, 1.0 second.

2

.

Create a tie on the matrix switcher from desired input X to the output

number that corresponds to MGP window Y, in which input X will be
displayed.

3

.

Immediately (within 1 second) recall the input preset with the same number

as switcher input X that you selected in step 2 (preset X), to MGP window Y.

Input presets cannot be recalled via the MGP front panel. You can recall them
via SIS commands (see chapter 4), the MGP 462 Web pages (see chapter 5), or
the Windows-based control software (see chapter 4 and the control software’s
Help).