Software Configuration and Control, cont’d

MGP 462 • Software Configuration and Control

4-18

Backgr

ound color

, continued

Set user

-defined color levels

X

!

*

X

!

*

X

!

*

22#

Ubk

X

!

*

X

!

*

X

!

Set the r

ed, gr

een, and blue values for the

user

-defined color

.

X

!

= 0-255 level scale.

Example:

50

* 100

* 150

* 22#

Ubk 50

* 100

* 150

The r

ed, gr

een, and blue levels for the user

-

defined colors ar

e 50, 100, and 150,

respectively

.

V

iew user

-defined color levels

22#

Ubk

X

!

*

X

!

*

X

!

Show the r

ed, gr

een, and blue levels for the

user

-defined colors.

Film mode

Enable Film mode

X5

5

* 1 * 18#

X5

5

Flm1

Enable Film mode. (Auto-senses for 3:2 or

2:2 pull-down.)

Disable Film mode

X5

5

* 0 * 18#

X5

5

Flm0

Disable Film mode.

V

iew Film mode status

X5

5

* 18#

0

(of

f) or 1

(on)

V

iew the curr

ent Film mode setting.

Auto Image

Run

Auto Image

X5

7

* 55#

Aut

X5

7

Perform

Auto Image adjustment on window

X5

7

.

Bi-dir

ectional serial data port

Send data string

Esc

X1

*

X1

7

*

X

20

*

X2

1

RS

X2

W

X1

%2A

X1

7

%2A

X

20

%2A

X2

1

RS

|

X2

Response fr

om command

X1

= port number (01-99).

X1

7

= time in tens of milliseconds that the MGP will wait until r

eceipt of the first r

esponse character befor

e terminating the command

(default = 10 = 100 ms, max. = 32767).

X

20

= time in tens of ms that the MGP will wait

between characters

being r

eceived via a serial port befor

e terminating the curr

ent command or r

eceive operation

(default = 2 = 20 ms, max. = 32767).

X2

1

= #L

or

#D. The letter parameter is case sensitive (r

equir

es capital D or capital L).

L =

L

ength of the message to be r

eceived.

D =

D

elimiter value

# = byte count (for L) or a single ASCII character expr

essed in decimal form (for D).

Byte count # can be fr

om 0 to 32767, default = 0. The ASCII decimal # can be fr

om 0 to 00255, default = the byte count. A

3-byte length = 3L.

A delimiter of ASCII 0A = 10D.

The r

esponse includes leading zer

os.

X

2

= command data section. For W

eb encoding for

X2

, be sur

e to convert nonalphanumeric characters to hex numbers.

Example:

Esc

05*4*7*3L RS

<data>•

W05%2A4%2A7%2A3L RS

|

<data>

Response fr

om command

The *

X1

7

*

X

20

*

X2

1

sequence is optional. If

X1

7

and

X

20

are not specified, the default values ar

e used.

Command/r

esponse table for IP contr

ol port commands

Command

ASCII (T

elnet)

URL Encoded (W

e

b

)

Response

Additional description

(host to pr

ocessor)

(host to pr

ocessor)

(processor to host)

Advertising
This manual is related to the following products: