Remote control connector, Output connectors, Power connector – Extron Electronics MGP 462D User Manual

Page 21

Advertising
background image

2-7

MGP 462 • Installation

Remote control connector

7

RS-232/422 connector —

Plug a computer or other

RS-232 or RS-422 host device into this female D-sub
connector. Wire the connector as shown in the tables
below. For more information on controlling the
MGP 462 remotely, see chapter 4, Software Configuration
and Control
.

Pin assignments for the RS-232/422 connector

Output connectors

8

Output connectors —

Plug one or two output devices into the 5-BNC and/or

the 15-pin HD connector. (When two output devices are attached, they both
display the same picture.)

R

/R-Y

G

/Y

B

/B-Y

H

V

S

R

/R-Y

G

/Y

B

/B-Y

H

V

S

R

/R-Y

G

/Y

B

/B-Y

H

V

S

R

/R-Y

G

/Y

B

/B-Y

H

V

S

RGBHV

RGBS

RGsB

HDTV Component Video

BNC output connectors

Power connector

9

AC power connector —

Plug the power cord provided with the MGP 462 into

this connector to connect the MGP 462 to a 100–250 VAC, 50/60 Hz power
source.

5

1

9

6

Pin RS-232

function Description

1 –

No

connection

2

Tx

Transmit data

3

Rx

Receive data

4

No connection

5

Gnd

Signal ground

6 –

No

connection

7

No

connection

8

No connection

9

No connection

Pin RS-422

function Description

1 – No

connection

2

Tx-

Transmit ground

3

Rx-

Receive ground

4

– No

connection

5

Gnd

Signal ground

6 – No

connection

7

Rx+

Receive data

8

Tx+

Transmit data

9

No connection

Advertising