Multi-turn actuators SA 07.1 – SA 48.1 / SAR 07.1 – SAR 30.1
AUMA NORM

Operation instructions

Service conditions

Output drive types

A, B1, B2, B3, B4 according ISO 5210 (A, B2, B4 according to MSS SP-102)

A, B, D, E according to DIN 3210
C according to DIN 3338
Special output drives: AF, AK, AG, IB1, IB3

Enclosure protection
according to EN 60 529

2)

Standard:

IP 67

Options:

IP 68
IP 67-DS (Double Sealed)
IP 68-DS (Double Sealed)
(Double Sealed = additional protection of the interior of the housing
against ingress of dust and dirt when removing the plug)

Corrosion protection

Standard:

KN

Suitable for installation in industrial units,
in water or power plants with a low pollutant concentration

Options:

KS

Suitable for installation in occasionally or permanently aggressive
atmosphere with a moderate pollutant concentration (e.g. in
wastewater treatment plants, chemical industry)

KX

Suitable for installation in extremely aggressive atmosphere with high
humidity and high pollutant concentration

KX-G

Same as KX, however aluminium-free version (outer parts)

Finish coating

Standard:

Two part acrylic polyurethane

Color

Standard:

Dark grey (DB 702, similar to RAL 9007)

Option:

Other colours are possible on request

Ambient temperature

3)

Standard:

SA

– 20 to + 80 °C/ – 20 to + 175 °F

SAR

– 25 to + 60 °C/ – 20 to + 140 °F

Options:

SA

– 40 to + 60 °C/ – 40 to + 140 °F (low temperature)
– 50 to + 60 °C/ – 58 to + 140 °F (extreme low temperature)
– 60 to + 60 °C/ – 75 to + 140 °F (extreme low temperature)
– 0 to + 120 °C/ + 32 to + 250 °F (high temperature)

SAR

– 40 to + 60 °C/ – 40 to + 140 °F (low temperature)

Vibration resistance
according to IEC 60068-2-6

2 g, for 10 to 200 Hz (only for sizes SA(R) 07.1 – SA(R) 16.1 without controls)
Resistant to vibrations during start-up or for failures of the plant.
However, a fatigue strength may not be derived from this.
Valid for multi-turn actuators in version AUMA NORM (with AUMA plug/socket connector, without
actuator controls). Not valid in combination with gearboxes

Lifetime

4)

SA 07.1 – SA 10.1

20,000 operating cycles (OPEN - CLOSE - OPEN)
with 30 turns per stroke

SA 14.1 – SA 16.1

15,000 operating cycles

SA 25.1 – SA 30.1

10,000 operating cycles

SA 35.1 – SA 48.1

5,000 operating cycles

SAR 07.1 – SAR 10.1

4)

5 millon starts

SAR 14.1 – SAR 16.1

4)

3.5 million starts

SAR 25.1 – SAR 30.1

4)

2.5 million starts

Other information

Reference documents

Product description “Electric multi-turn actuators SA”
Dimension sheets SA(R)
Electrical data sheets SA/SAR
Technical data sheets SA/SAR

2) For 3-phase asynchronous motors in enclosure protection IP 68, higher corrosion protection KS or KX is strongly recommended. Additionally, for enclosure

protection IP 68, we recommend to use the double sealed terminal compartment DS.
For 1-phase AC motors, DC motors, or special motors, the enclosure protection according the name plate applies.

3) Versions with RWG up to max. to + 158 °F

4) The lifetime depends on the load and the number of starts. A high starting frequency will rarely improve the modulating accuracy. To reach the longest possible

maintenance and fault-free operation time, the number of starts per hour chosen should be as low as permissible for the process.