4.

Transport, storage and packaging

4.1

Transport

.

For transport to place of installation, use sturdy packaging.

.

Do not attach ropes or hooks to the handwheel for the purpose of lifting by hoist.

.

If multi-turn actuator is mounted on valve, attach ropes or hooks for the purpose
of lifting by hoist to valve and not to multi-turn actuator.

Fitting the handwheel:

For transport purposes, handwheels from a diameter of 400 mm (1 inch
corresponds to 25.4 mm) are supplied separately.

Engage manual operation prior to mounting the handwheel! If the
manual operation is not engaged, damages can occur at the
change-over mechanism.

.

Engage manual operation (figure A-1):
Manually lift the red change-over lever while slightly turning the shaft back and
forth until manual operation engages. The manual operation is correctly engaged
if the change-over lever can be lifted by approx. 85°.

Manual force is sufficient for operating the change-over lever. It is
not necessary to use an extension. Excessive force may damage
the change-over mechanism.

.

Install the hand wheel over the red change-over lever on to the shaft (figure A-2).

.

Secure handwheel using the snapring supplied.

4.2

Storage

.

Store in well-ventilated, dry room.

.

Protect against floor dampness by storage on a shelf or on
a wooden pallet.

.

Cover to protect against dust and dirt.

.

Apply suitable corrosion protection agent to uncoated surfaces.

If multi-turn actuators are to be stored for a long time (more than 6 months), in
addition, the following points must imperatively be observed :

.

Prior to storage: Protect uncoated surfaces, in particular the output drive parts
and mounting surface, with long-term corrosion protection agent.

.

Check for corrosion approximately every 6 months. If first signs of corrosion
show, apply new corrosion protection.

After mounting, connect actuator immediately to electrical system,
so that the heater prevents condensation.

4.3

Packaging

Our products are protected by special packaging for the transport ex works. The
packaging consists of environmentally friendly materials which can easily be
separated and recycled.

7

Multi-turn actuators SA 07.1 – SA 48.1 / SAR 07.1 – SAR 30.1

Operation instructions

AUMA NORM

85°

Figure A-1

Figure A-2