MoTeC PWC Plug-In ECU User Manual

Page 79

Advertising
background image

72

Appendices

MoTeC

Calibration and Wiring Notes

Note 1 – Calibration Functions

The following pins are calibrated in the Base Maps with the function and
parameters as mentioned in the table.

M400 Pin

Hydro S4 Pin

Function

Parameters

Aux1 A18 G04

9: Lambda Heater Lambda Sensor 1

Aux2 A01 C33

3: Aux Table

PWM/Switched 0
Output Mode 0
Polarity 0
Frequency 10
Minimum Duty Cycle 0
Maximum Duty Cycle 100
Hysteresis 0

Aux3 A23 C26

3: Aux Table

PWM/Switched 1
Output Mode 0
Polarity 0
Frequency 10
Minimum Duty Cycle 0
Maximum Duty Cycle 100
Hysteresis 0

Aux4 A24 C29

1: Boost Control

Frequency 50
Polarity 0
Output Mode 0

Aux5 A31 C34

101: Fuel Pump

Delay 0.5
Polarity 0
Output Mode 0

Aux6 A32

0: Off

Aux7 A33

0: Off

Aux8 A34

0: Off

AT3

B05 C19

4: Dual RPM limit

Logic Polarity 0
Low RPM Limit 2400
RPM Rise Rate 0
Ignition Retard 26

Advertising