Spaces around the cabinet, Starting & testing the unit – American Panel HURRICHILL AP20BC175-2 User Manual

Page 10

Advertising
background image

AP20BC175-2 Manual

9

SPACES AROUND THE CABINET


• At least 15" clear space is required above

the unit for service.


• At least 6" clear space is required on both

sides of the cabinet.


• At least 6" clear space is required on the

rear of the cabinet for drain hookup and
maintenance.


• Enough space should be provided in front

of the cabinet to fully open the door.


















STARTING & TESTING THE UNIT


1.
To charge the unit, use the "HARD" cycle and the "MANUAL" mode. Set for two hours of
operation to allow enough time to fully charge the unit.

2.
Start the unit per 1. above and in accordance with the following operating instructions, then
perform at least one complete blast chilling or shock freezing cycle. When done, instruct the client
on the correct use of the unit.

3.
By the end of the cycle the unit should have pulled down to10

o

F. It should have been cycling

between 10

o

F and 20

o

and the sight glass must be clear.


4.
As soon as possible after the unit has been started, check the power consumption, the standard
pressure measurements and the operation of all the controls.

NOTE: The refrigerating system works on pressure. An electro valve mounted on the top of the
cabinet is controlled by the electronic controller. When the temperature of the air in the cabinet falls
to the programmed low temp setting, the electro valve will close (0 VAC) and the unit will pump
down. When the temperature of the air in the cabinet rises to the programmed high temp setting,
the electro valve will open and refrigeration will start.