INTRODUCTION


Blast Chiller Model AP20BC175-2 is used to rapidly chill cooked foods to temperatures suitable for
refrigerated storage. It is capable of lowering the core temperature of up to 200 pounds of most
foods from 160

o

F to 40

o

F in 90 minutes. Food is loaded into 12" x 20" x 2-1/2" pans. All units are

sized to accept one rack containing up to 20 pans. Model AP20BC175-2 has an integral
temperature recording device (printer) and 4 food probes. It employs a high velocity flow of cooled
air to assure even cooling of the food product, and to quickly bring the food temperature through
the danger zone in which bacteria multiply rapidly. This is done in accordance with the
requirements of HACCP, FDA and all applicable state regulations.

CONTROLLER FEATURES


The electronic control system is solid state and is based on the latest microprocessor technology.
The display is VFD Industrial Type. It displays 4 lines of 20 characters each and allows operator
viewing from any angle. The display is programmed to show clear step-by-step instructions and
operating data. It is capable of storing 250 sets of data and 150 recipes. The unit has built-in safety
and self-diagnostic systems. The controller notifies the operator if various faults, as listed below,
should occur:

¾ Power supply failure / Restoration of power
¾ Faulty air temperature probe
¾ Faulty food temperature probe
¾ High air temperature (above 140

o

F)

¾ Low air temperature (below 0

o

F)

¾ High food temperature (above 180

o

F)

¾ Low food temperature (below 35

o

F)

As an option, the unit can be operated by a PC. The PC interface allows the operator to remotely
program the unit, operate it, download the data and print the data.

OPERATING MODES


The operator can choose from the following modes:

AUTOMATIC MODE

This is the preferred mode, in which all the food probes are active and take part in controlling the
chilling or freezing process. The cycle will never proceed to its next step until all the probes have
reached their set breaking temperatures. The operator needs only to select the recipe number of
the food to be controlled by each probe (up to 150 recipes can be programmed), then insert each
probe into its food. It is recommended that the operator remove the food when its temperature
starts to flash and the display shows “Ready”. The unit will automatically switch into holding mode
(cavity air temperature between 35

o

F and 42

o

F) when all the food have reached the end cycle

programmed temperature.

MANUAL MODE

Operating time is set manually, by the operator, for the meal that has been chosen. Air
temperature is controlled by the air probe. If the food probes have been inserted into the food they
will provide temperature readouts only. The unit will automatically switch into the holding mode at
the end of the cycle.