Installation, Warnings, Preparation – American Panel HURRICHILL AP20BC175-2 User Manual

Page 8: Location, Dimensions, Electrical and refrigeration specifications

Advertising
background image

AP20BC175-2 Manual

7

INSTALLATION

WARNINGS


READ ALL OF THE INSTRUCTIONS IN THIS MANUAL BEFORE YOU ATTEMPT TO INSTALL
THE EQUIPMENT AND CAREFULLY FOLLOW THEM.

ALWAYS DISCONNECT THE UNIT FROM THE POWER SOURCE BEFORE PERFORMING
ANY SERVICE OR MAINTENANCE.

INSTALLATION AND SERVICE MUST BE PERFORMED BY A QUALIFIED SERVICE AGENCY
APPROVED & AUTHORIZED BY AMERICAN PANEL CORPORATION. DOING OTHERWISE
MAY VOID THE WARRANTY.

Note: Any changes made to the equipment without authorization from the factory will void
the warranty.

PREPARATION

9 Check the integrity of the unit once it is unpacked.
9 Check that the available power supply corresponds to the ratings on the unit's nameplates

and that correctly rated electrical protection is provided.

9 Quick disconnect must be provided for this unit by the installer.
9 If additional refrigerant should be needed, be certain to use the correct type.
9 Make certain that adequate drainage is provided.

Ambient air temperature should be no greater than 90

o

F to ensure the rated performance.


INSTALLATION


THIS MODEL HAS REMOTE CONDENSING UNIT. The condensing unit and the cabinet must be
connected and installed in accordance with the following instructions:

LOCATION

Ambient air temperature for air cooled condensing units should be no greater than 90

o

F to ensure

the rated performance. A remote condensing unit must be located away from direct sunlight if
installed outdoors, or, if it is indoors, a water cooled condensing unit should be used.

DIMENSIONS

Overall dimensions are 47-1/2 " left to right, 42" front to back, 86-1/2" height. With the door open
90

o

the front to back distance is 72-1/2".

ELECTRICAL AND REFRIGERATION SPECIFICATIONS

CABINET REMOTE

CONSENSER

MODEL VOLTAGE

AMPS

POWER SUPPLY

CORD

BTU/H AT 14°F EVAP. TEMP.

& 105°F COND. TEMP.

AP20BC175-2 208/1/60 8

14-3

25,000


NOTES:

1. The condensing unit and the cabinet must be connected to separate electrical power supplies.
2. Each wire must be connected to its corresponding terminal.
3. The ground wire must be connected to an efficient ground terminal.