Inclinometer RS232

– Current Datasheet

Version: 20130503

INCLI NO MET E R

RS2 32

– CURRENT

1 Technical Data

1.1 Electrical Data

Model

INC 5

INC 15

INC 30

Measuring range

+/- 5°

+/- 15°

+/- 30°

Resolution digital

0.001°

0.001°

0.01°

Resolution analog

0,001°

0,005°

0,01°

Accuracy Digital

1)

+/-0,01°

+/-0,01°

+/-0,02°

Accuracy Analog

1)

+/-0,05°

+/-0,05°

+/-0,05°

Temperture Gradient

2)

+0.001°/K

+0.002°/K

+0.003°/K

Inclination angle in x and y

1)

+/-15°

+/-40°

+/-60°

Damping period 5° > 0°

Typical 1 s 10 %, 2 s 1 %, 3 s 0.1 %

Digital interface

RS232 format ASCII

Baud rate

Max. 56 k

Analog interface

4 to 20mA, 0°= 12mA, Load 300 Ohm

Supply voltage

4)

10 to 30 V DC (absolute limits)

Current consumption

Typical 50 mA

EMC

Emitted interference: EN 61000-6-3

Noise immunity: EN 61000-6-2

Electrical lifetime

> 10

5

h

1) T = +25°C, 90% total measurement range

2) e.g. temperature drift AGS005 (T= 0°C up to +55°C) = 55K * 0,001°/K = 0,055°

3) Supply voltage is applied.

4) Inclinometers should be connected only to subsequent electronics whose power supplies comply with EN 50178 (protective low

voltage)