2-4

Section 2 Installation

Installation and Operation Manual

X-VA-MT3600-eng

Part Number: 541B075AAG

February, 2011

Models MT3600, MT3601 & MT3602

2-8 Electrical Connections - Alarm

Refer to Figure 1-7 for internal wiring to terminal strip for reed switch only.

Refer to Figure 1-8 for internal wiring to terminal strip for one reed switch
and one DPDT electromechanical relay.

Refer to Figure 1-9 for internal wiring to terminal strip for two reed switches
and two SPDT electromechanical relays.

Refer to Figures 1-10 and 1-11 for control drawing for IS or Division 2
installations.

2-9 Electrical Installation Requirements

Earthing Instruction:

Refer to Figures 1-7 through Figures 1-10.

Supply wiring:

The temperature rating of all wiring must be minimum of 75°C.

Overcurrent Protection: