Brooks Instrument 3600 Series User Manual

Page 8

Advertising
background image

1-2

Section 1 Introduction

Installation and Operation Manual

X-VA-MT3600-eng

Part Number: 541B075AAG

February, 2011

Models MT3600, MT3601 & MT3602

Ambient Temperature Limits
-20°F to 122°F (-29°C to 50°C)

Operating Fluid Temperature Limits
Maximum: 500°F (260°C)
Minimum: -20°F (-29°C)

Minimum/Maximum temperature with:
Buna O-ring -20°F (-29°C) to 250°F (121°C)
EPR O-ring: -20°F (-29°C) to 300°F (149°C)
Kalrez

®

O-ring: -20°F (-29°C) to 400°F (204°C)

Metal (316SS) O-ring: -20°F (-29°C) to 400°F (204°C)
Silicone O-ring: -20°F (-29°C) to 400°F (204°C)
Teflon

®

O-ring: -20°F (-29°C) to 400°F (204°C)

Viton

®

fluoroelastomers O-ring: -20°F (-29°C) to 400°F (204°C)

Optional all welded construction: 500°F (260°C)
Note: Maximum Temperature Rating for all meters with alarm option is
250°F (121°C)

Materials of Construction

Metering Tube, Floats, Flanges, and Extension Well
Standard: 316 stainless steel
Optional: Monel™, Hastelloy C-276™, “Mill Certificates” (316 stainless
steel only), meter body per NACE Spec MR-01-75 (316 stainless steel
only)

Table 1-1 Capacities and Pressure Drop

1. All air flows given are at 14.7 psia and 70°F.
2. 1" and 1-1/2" meters not recommended for gas service,

due to stability of float.

3. Minimum operating pressure (downstream) on gas service is 35 psig for

1/2" size. Consult factory for other conditions.

Size 8

Size 10 (1")

Size 12 (1-1/2")

Pressure

Pressure

Pressure

Air

Water

Drop

Water

Drop

Water

Drop

scfh

gph

psi

gpm

psi

gpm

psi

23

5

_

5

1.75

20

2.00

58

15

1.25

_

_

30

2.75

120

30

1.50

10

3.75

40

4.75

195

50

1.00

15

4.75

50

5.75

425

100

1.50

_

_

_

_

790

180

3.25

_

_

_

_

1660

300

5.00

_

_

_

_

Advertising