Electrical data – Burkert Type 8694 User Manual

Page 10

Advertising
background image

10

Technicaldata

6.7. Electrical data

6.7.1. Electrical data without bus control

24 V DC

Connections

Cable gland M16 x 1.5, wrench size 22
(clamping area 5 – 10 mm)
with screw-type terminals for cable cross-
sections 0.14 – 1.5 mm²
Circular plug-in connector
(M12 x 1, 8-pole)

Pilot valve
Supply voltage

24 V DC ± 10 %
- max. residual ripple 10 %

Power input

≤ 3,5 W

Input resistance for
set-point value signal

75 Ω at 0/4 – 20 mA /
12 bit resolution

Protection class

3 in accordance with VDE 0580

Analogue position
feedback max. load
for current output
0/4 – 20 mA

560 Ω

Binary input

0 – 5 V = log “0”,
12 – 30 V = log “1”
inverted input in reverse order

Communications
interface

Direct connection to PC via USB
adapter with integrated interface
driver, communication with communi-
cations software based on FDT/DTM
technology.

6.7.2. Electrical data with AS interface bus

control

Connections

Circular plug-in connector
(M12 x 1, 4-pole)

Electrical supply voltage

29.5 V – 31.6 V DC
(according to specification)

Devices without external supply voltage:

Max. power consumption

150 mA

Devices with external supply voltage:

External supply voltage

24 V ± 10 %

The power supply unit must include a secure disconnection in

accordance with IEC 364-4-41(PELV or SELV)

Max. power consumption

100 mA

Max. power consumption
from AS interface

50 mA