Model for control of third-party devices – Burkert Type 8696 User Manual

Page 8

Advertising
background image

8

Systemdescription

Pilot air port
(label: 1)

Exhaust air port
(label: 3)

Electrical connection
(circular plug-in connector)

DIP Switches

Key 2

Key 1

LED 1

LED 2

Communications

interface

Transparent cap removed:

Pressure limiting valve

(for protection against

too high internal pressure

in case of error)

Fig. 2:

Structure 2

The position of the actuator is regulated according to the position
set-point value. The nominal position value is specified by an external
standard signal.

5.2. Model for control of third-party

devices

A special model enables the positioner Type 8696 to be attached to
third-party devices.
This model has a different pneumatic connection module so that the
pilot air ports can be connected to the outside of the actuator.

Electrical connection
(circular plug-in connector)
Exhaust air port
(label: 3)

Pilot air port
(label: 1)

Fastening screws (2 x)

Pilot air outlet 2

2

Pilot air outlet 2

1

Fig. 3:

Model for third-party devices

NOTE!

Damage or malfunction due to ingress of dirt and moisture!
• To comply with protection class IP65 / IP67, connect the pilot

air outlet

(only for CFA or CFB) which is not required to the free

pilot air port of the third-party device or seal with a plug.

english

Type 8696