Technicaldata

6.5.

Pneumatic data

Control medium

neutral gases, air
Quality classes in accordance with DIN ISO 8573-1

Dust content

Class 5

max. particle size 40 µm, max. particle density 10 mg/m³

Water content Class 3

max. pressure dew point
- 20 °C or min. 10 °C below the lowest operating temperature

Oil content

Class 5

max. 25 mg/m³

Temperature range
of the compressed air

0 ... +60 °C

Pressure range

3 ... 7 bar

Air output of control valve

7 l

N

/ min (for aeration and deaeration)

(Q

Nn

- value according to definition for pressure drop from 7 to 6 bar absolute)

optional:
130 l

N

/ min (for aeration and deaeration)

(only single-acting)

Connections

Plug-in hose connector Ø6 mm / 1/4"
Socket connection G1/8

6.6.

Type label

8694 24 V DC

single act Pilot 0,6

Pmax 7bar

Tamb 0°C - +60°C

S/N 001000

00185134

D-74653

Ingelfingen

W14UN

CE

Identification number

Supply voltage / Control

Nominal pressure

Type

Control function - Pilot valve

Bar-code

Serial number - CE mark

Max. ambient temperature

Figure 7:

Example of type label