Burkert Type 8694 User Manual

Page 37

Advertising
background image

37

Installation

2. Install positioner

Push the positioner onto the actuator. The puck holder must be aligned in such a way that it is inserted into
the guide rail of the positioner.

NOTE!

Damaged printed circuit board or malfunction!

• Ensure that the puck holder is situated flat on the guide rail.

Guide rail

Puck holder

Figure 21:

Aligning the puck holder

Press the positioner all the way down as far as the actuator and turn it into the required position.

Fastening screws

max. 0.5 Nm

Figure 22:

Installing the positioner

Ensure that the pneumatic connections of the positioner and those of the valve actuator are situated pref-
erably vertically one above the other.
If they are positioned differently, longer hoses may be required other than those supplied in the accessory kit.

NOTE!

Too high torque when screwing in the fastening screw does not ensure protection class IP65 / IP67!

• The fastening screws may be tightened to a maximum torque of 0.5 Nm only.

Attach the positioner to the actuator using the two side fastening screws. In doing so, tighten the fastening
screws hand-tight only (maximum torque: 0.5 Nm).

English

Type 8694

Advertising