Disassembly

17.

DISASSEMBLY

17.1. Safety instructions

DANGER!

Risk of injury from high pressure!

• Before dismounting pneumatic lines and valves, turn off the pressure and vent the lines.

Risk of electric shock!

• Before reaching into the device or the equipment, switch off the power supply and secure to prevent

reactivation!

• Observe applicable accident prevention and safety regulations for electrical equipment!

WARNING!

Risk of injury from improper disassembly!

• Disassembly may be carried out by authorized technicians only and with the appropriate tools!

Risk of injury from unintentional activation of the system and an uncontrolled restart!

• Secure system from unintentional activation.

• Following disassembly, ensure a controlled restart.

17.2. Disassembly the positioner

Procedure:

1. Pneumatic connection

DANGER!

Risk of injury from high pressure!

• Before dismounting pneumatic lines and valves, turn off the pressure and vent the lines.

Loosen the pneumatic connection.

Series 20xx:
Loosen the pneumatic connection between positioner and actuator.

English