Burkert Type 8644 User Manual

Page 18

Advertising
background image

18

TechnicalData

ambient temperature

0 ... +55 °C

0 ... +55 °C

0 ... +55 °C

Operating voltage

24 V / DC, -15 % / +20 % tolerance**,

Residual ripple for field bus interface 5 %

* Power reduction (in the module)
** For the Ex-version maximum +10 %
*** The following restrictions apply to the power supply tolerances of the entire system (see Technical Data of the

entire system): Valve type: 0460 ± 10 %

add-on dimension

16.5 mm

Operating principle
Valve

C/D (3/2-way)

Type 6526

L/N (5/3-way)

Type 0461***

Operating principle
Valve

H (5/2-way)

Type 6527

H (5/2-impulse)

Type 0461

flow-rate

700 l/min

500 l/min

pressure range
(with p shut-off)

2 ... 10 bar

2.5 ... 7 bar

Output

1 W

2 W

2 x 1 W

current before
power reduction

42 mA

85 mA

41 mA

current after
power reduction

33 mA

52 mA

-

Valve locations (max.)

32

24

electrical modules

2-fold, 3-fold*, 4-fold

2-fold bistable

pneumatic modules

2-fold, 3-fold*, 4-fold

2-fold bistable

ambient temperature

0 ... +55° C

0 ... +55° C

Operating voltage

24 V / DC, -15 % / +20 % tolerance**,

Residual ripple for field bus interface 5 %

* 3 x 10 mm valves for add-on dimension of 16.5
** For the Ex-version maximum +10 %
*** The following restrictions apply to the power supply tolerances of the entire system (see Technical Data of the

entire system): Valve type: 0461 ± 10 %

interface (prOfiBus)

PROFIBUS

Copper line (RS-485), connected via PROFIBUS plug,
supply isolated, shielding connected galvanically to the functional earth

Recommended cable lengths

see PROFIBUS system data

english

Type 8644