Structureandfunctionofthemodules

Combination options (electronic base module / valve)

Base module type

add-on

dimension

Valve locations

Valve type

Operating principle

ME02

2-fold
monostable

11 mm

2

6524

3/2-way

6525

5/2-way

2-fold
bistable

11 mm

2

0460

5/3-way
5/2-way impulse

2-fold
2 x monostable

11 mm

2

6524

2 x 3/2-way

4-fold
monostable

11 mm

4

6524

3/2-way

6525

5/2-way

ME03

2-fold
monostable

16.5 mm

2

6526

3/2-way

6527

5/2-way

2-fold
bistable

16.5 mm

2

0461

5/3-way
5/2-way impulse

3-fold
10 mm monostable*

11 mm

3

6524

3/2-way

6525

5/2-way

4-fold
monostable

16.5 mm

4

6526

3/2-way

6527

5/2-way

* with 10 mm valves

The connector strip situated under a shielding plate near the electronic base modules is guided by a protective
plastic collar. Placing these modules in rows and connecting them together ensure that this shielding plate
and the plug pins are not damaged or bent.