Fluid installation – Burkert Type 8644 User Manual

Page 57

Advertising
background image

57

Installation

Place new function module vertically on the distributor module (backplane bus) and press down until it clicks
into position.

Connect valve, with the cleanly inserted flange seals / O-rings, to the valve slot and tighten the screws
according to the following assembly diagram (see “Figure 30: Tightening the screws”).



20 Ncm

20 Ncm 30 Ncm

30 Ncm

Figure 30:

Tightening the screws

8.5.

fluid installation

DANgEr!

risk of injury from high pressure in the equipment!

• Before dismounting pneumatic lines and valves, turn off the pressure and vent the lines.

• Design the connections with the largest possible volume.

• Close the open connections not required with lock screws.

• The connections for the pilot control exhaust air (x) must not be sealed.

• Check that connections 1 and 3 or 5 have been configured correctly; these must not be mixed up.

english

Type 8644