English, 7maintenance – Burkert Type TAT002 User Manual

Page 20

Advertising
background image

18 - 0911

english

7

MAINTENANCE

When operated in accordance with the instruction in this handbook, the 0911
controller is maintenance-free.

PA

1

Description

Range

Default

PE

2

UCI

3

Upper analog display

value

depending on sensor

var.

Pr2

Opb

Sensor calibration

depending on measurement

range

0

Pr1

rES

Resolution

in = NO; dE = 0.1; cE = 0.01

in

Pr2

UdM

Units

Type TU: °C = °C, °F = °F;

Type AU: 0 = °C, 1 = °F;

2 = RH, 3 = bar, 4 = PS,

5 = without display

var.

Pr1

PbC

Type of sensor

Pt = Pt100; J = tcJ; c = tck;

S = tcS; Ptc = PTC;

ntc = NTC; 0.1 = 0...1 V;

10 = 0...10 V; cur = 0...20 mA

var.

Pr1

P3F

3

rd

sensor present

no = no; yES = yes

no

Pr2

HES

Energy-saving mode

Down scale / Full scale

0

Pr2

i1F

Configuration of the

digital input

c-H / oFF / off / HES /

EAL / bAL

EAL

Pr2

i1P

Polarity of the digital

input

cL = closed;

oP = open

cL

Pr2

did

Alarm delay of the digital

input

0...120 min

0

Pr2

Adr

Serial address for XJ500

RS485 address

1

Pr2

OnF

Activate Standby

function

no = no; oFF = active

no

Pr2

Ptb

Parameter table

Read value

-

Pr2

rEL

Software version

Read value

-

Pr2

Pr2

Parameter access to Pr2

Read value

321

Pr1

1

Parameter

2

Programming level

3

Only for devices with voltage and current input

Advertising
This manual is related to the following products: