Burkert Type 8076 User Manual

Page 8

Advertising
background image

8

Technical data

Type 8026- 8036- 8076

6.2.2. conformity to the pressure directive

of flowmeters 8026 and fittings
s030 and s070

The devices 8026 and the fittings S030 and S070 comply with
article 3§3 of the pressure directive.
Acc. to the 97/23/CE pressure directive, the product can only be
used in the following cases (depending on max. pressure, pipe dia-
meter and fluid):

type of fluid

conditions

Fluid group 1, par.
1.3.a

• Flowmeter 8026 and fitting S030:

DN

25 only

• Fitting S070: Forbidden

Fluid group 2 par. 1.3.a DN ≤ 32

or DN > 32 and PNxDN

≤ 1000

Fluid group 1 par. 1.3.b • Flowmeter 8026: DN ≤ 25

or DN > 25 and PNxDN ≤ 2000

• Fittings S030 and S070:

PNxDN ≤ 2000

Fluid group 2 par. 1.3.b • Flowmeter 8026: DN ≤ 400

• Fittings S030 and S070: DN

200

6.3.

General technical data

6.3.1. mechanical data

part

material

Box / seals

stainless steel 1.4404, PPS /
EPDM

Cover / seal

PC / EPDM

Display module

PC / PBT

M12 fixed connector

nickel-plated brass

Fixed connector holder

stainless steel 1.4404 (316L)

Screws

Stainless steel

Nut

PC

Flow sensor holder / seal (only
8026)

PVDF / FKM (default)

Axis and shaft of the paddle
wheel (only 8026)

Ceramic (Al

2

O

3

)

Paddle wheel (only 8026)

PVDF

Quarter-turn system (only SE36) PC