Operation stage on input 1 and 2 (batch function), Se 56 – Burkert Type 8056 User Manual

Page 16

Advertising
background image

SE 56

16

T

T

T

Start batch via input 1 stop from output selection

formula 00 o 01 via input 2

Block totalizer via input 1 start via input 2

Block and reset totalizer from remote input 1

start batch from remote input 2 consent mode to batch enable

OPERATION STAGE ON INPUT 1 AND 2 (BATCH FUNCTION)









































Necessary conditions for enabling the function

‰

POS. 5.10 ENABLED

‰

POS. 6.1 or 6.4 on BATCH

‰

POS. 5.10 ENABLED function of

formula selection 00/01 assigned to input 2
(optional)

The signal block for the totalizer always
interrupts the batch. By re-energizing
input it is 2 possible to get 2 results:
1) T< 1Sec = restart interrupted
batch

2) T between 1 and 4 sec = reset
interrupted batch. Note: will be

necessary to give a new start

impulse to the input 2 (T< 1Sec)

to begin a new batch

Necessary conditions for enabling the

function

‰

POS.

5.6 ENABLED (Block

totalizer)

‰

POS. 6.1 or 6.4 on END BATCH

‰

POS. 5.10 ENABLED (Batch
function for input 2 (optional))

‰

POS. 5.2 ENABLED (P+)

The signal block for the totalizer (Input 1
signal) always stops the batch. With the T2
reset function enabled through the stopping of
the input 1 signal the batch totalizer goes to
zero. With the totalizer at zero a new pulse on
Input 2 will restart a new batch.

Necessary conditions for enabling the function

‰

POS. 5.6 ENABLED (Block totalizer)

‰

POS. 5.11 ENABLED Batch function
assigned to input 2 (optional)

‰

POS. 12.7 ENABLED (consent mode)

‰

POS. 5.2 ENABLED (P+)

3-40V

0-1.5V

Start

Opening
valve

Closing
valve

Opening
valve

Closing
valve

BATCH FORMULA 00

BATCH FORMULA 01

BATCH FORMULA 00

BATCH FORMULA 01

3-40V

IN

PU

T 2

OUT

P

UT

IN

PU

T 1

3-40V

0-1.5V

Start

Start

Opening
valve

Closing
valve

Opening
valve

Closing
valve

NEW BATCH

RESTART INTERRUPTED

BATCH

OUT

P

UT

OUT

P

UT

IN

PU

T 2

IN

PU

T 2

IN

PU

T 1

T

<1 Sec.

T be

twe

e

n

1

a

n

d 4

S

e

c.

3-40V

0-1.5V

Start

RESET

T<1 sec.

Start

Opening
valve

Closing
valve

Opening
valve

Closing
valve

INTERRUPTED BATCH

0-1.5V

3-40 V

BLOCK

0-1.5 V

3-40 V

Start

IN

PU

T 2

Opening
valve

Closing
valve

Opening
valve

Closing
valve

0-1.5V

3-40 V

BLOCK RESET

T2

IN

PU

T 1

OUT

P

UT

INTERRUPTED BATCH

NEW BATCH

INTERRUPTED BATCH