For each formula you can
associate:

‰ Product quantity

‰

Product name

‰

Maximum time for
batch (safety time for
each formula)


After activating the batch
function from visualization
page, proceed as
illustrated and described in
the aside example.

BATCH FUNCTION CONFUGURATION



VISUALIZATION PAGE WITH BATCH FUNCTION ENABLED



































CONFIGURATION of A

BATCH

Configuring formula n°

Product Name

Batch in progress

Visualizations:
1) batch off: n° batch effected
2) batch on: decrease safety timer
3) configuration: safety timer indefinite if
timer=0 timer disabled

Configuration of batch quantity

Visualization batched product

Input key code

Choose the formula number for associate
quantity batch (between 00 and 15)

Input quantity product for each batch

Enter product name for batch (max 8 characters)

Enter maximum time for batch
If timer = 0, safety timer disabled max time set
= 6000 sec.
Note: If one of the outputs has a batch alarm
assigned. Upon the completion of the batch or
an interruption, an alarm is activated.

From the visualization pages

ENABLE BATCH
Select one of the following functions to enable and configure the batch on the transmitter:
‰ POS. 5.9-5.10: START/STOP batch from input

‰ POS. 6.1-6.2: assign one of the functions ouputs one and/or two
Some examples of operation of such functions are visualized from page 14.

Long push

Long push

Vertical bars behavior

x

First bar: volume that is distributing, 100% represents the volume to be delivered, identified by the “drop” symbol

x

Second bar: dosing timer, 100% represents the security maximum time set for the batch, “T” symbol

x

Third bar: remains deviation measure, as a normal flow measure