6.1* Output 1 functions
6.2* Output 2 functions

6.3* Output 3 functions
6.4* Output 4 functions
6.5* Choice of the function and the range of current output n.1
6.6* Choice of the function and the range of current output n.2

8.3* Display contrast
8.4 Partial totalizer visualization (with batch enable the function is always on)
8.5 Date and time visualization with data logger enable
8.6 Quick start menu visualization
8.7 Enable the page of net totalizer (difference between direct and reverse)
8.8 Visualizes the values of the partial totalizers in the unit of selected currency

8.9 Choice of the numbers of decimals for the visualization currency value: From 0 to 3
8.10* Value of conversion/currency for direct totalizer
8.11* Value of conversion/currency for reverse totalizer

8.2 Display updating frequency: 1-2-5-10 Hz

8.1 Choice of the language: EN= English, IT=italian, FR= French, SP= Spanish, DE=German

8.12 Reset the processor of the display (useful in case of particular badly operations of the display)
8.13* Total direct (positive) flow totalizer reset
8.14* Partial direct (positive) flow totalizer reset
8.15* Total reverse (negative) flow totalizer reset
8.16* Partial reverse (negative) flow totalizer reset

7.1 Choice of the communication protocol for the IF2 device

7.2 Choice of the communication protocol for the RS232 port

7.11 Address value of converter (range 0 - 255)

7.3 Speed of the RS485 output (possible choices: 4800, 9600, 19200, 38400 bps)

7.5 Print function enable (optional)
7.6 Print of the performed batch

7.7 Print of the data process on regular intervals
7.8 Print of events

7.12 Address of a further converter connected like a terminal
7.13 Start remote connection to the terminal. Connection interrupted after 10sec. of inactivity

7.4 Speed of the RS232 output (possible choices: 4800, 9600, 19200, 38400 bps)

7.9 Instrument answer delay
7.10 RS485 parity













































5.1* Total direct (positive) flow totalizers reset enable
5.2* Partial direct (positive) flow totalizers reset enable
5.3* Total reverse (negative) flow totalizers reset enable
5.4* Partial reverse (negative) flow totalizers reset enable

5.6 Totalizers counting lock command (see page 14)

5.8* Autozero calibration external command
5.9 Range change external command (see function 3.5)
5.10 Batch start/stop external command (see batch functions)

5.11*Functions assigned to input 2

5.5 Reset totalizers of pulse from digital input (see page 14)

5.7* Block measures command