Installing a device with welding ends, Installing a device with clamp connections, Installing a device with flange connections – Burkert Type 8011 User Manual

Page 25

Advertising
background image

25

Installationandwiring

Type 8011

Correct

Incorrect

Fig. 7: Filling the pipe

7.2.2. installing a device with welding

ends

note

the se11 electronic module and the seal may be damaged
when welding the connections to the pipe.
• Before welding to the pipe, unscrew the 4 locking screws on

the SE11 electronic module.

• Remove the electronic module.
• Remove the seal.

Follow the installation recommendations in chap. 7.2.2.

Weld the connections.

After welding the connections to the pipe, correctly replace the
seal.

Properly replace the electronic module.

Tighten the 4 screws in an alternating pattern, applying a torque
of 1.5 Nm.

7.2.3. installing a device with clamp

connections

Follow the installation recommendations in chap. 7.2.1.

• Check that the seals are in good condition.
• Place the seals, that have been chosen depending on the

process temperature and fluid, into the grooves of the
Clamp connections.

Fit the Clamp connections to the pipe using a clamping collar.

7.2.4. installing a device with flange

connections

Follow the installation recommendations in chap. 7.2.1.

• Check that the seals are in good condition.
• Insert a seal, that has been chosen depending on the

process temperature and fluid, into the grooves of the
connections.

Make sure the seal remains in its groove when tightening
the flange.

Tighten the flange to mount the device to the pipe.