Technicaldata

Q

n

dn

flow

rate

range

c

onnection

o

utputs

o

rdering

codes

6 25

1 to
200 l/min

G 1 1/4'' ex-
ternal thread

Pulse, NPN

560132

Pulse, PNP +
4-20 mA, sourcing
mode

560114

NPT 1 1/4''
external
thread

Pulse, NPN

560616

Pulse, PNP +
4-20 mA, sourcing
mode

560621

6.

TechnicAl dATA

6.1.

conditions of use

Ambient temperature:

+5 to +55 °C

Storage temperature:

+5 to +55 °C

Air humidity:

< 80%, not condensated

Protection rating:

IP65 with cable plug plugged-in and

tightened

6.2.

conformity to standards and
directives

EMC: EN61000-6-3, 61000-6-2

Vibration: EN 60068-2-6

Shock: EN 60068-2-27

Pressure: complying with article 3 of §3 from 97/23/CE directive
For the 97/23/CE pressure directive, the device can only be used in
the following cases (depending on max. pressure, pipe diameter and
fluid)

type of fluid

conditions

Fluid group 1, §1.3.a

Forbidden

Fluid group 2, §1.3.a

Allowed (PN*DN

1000)

Fluid group 1, §1.3.b

Forbidden

Fluid group 2, §1.3.b

Allowed